描述
关键技术规格
| 参数项 | 参数值 |
|---|---|
| 完整物料号 | AI610 / 3BHT300000R1 |
| 通道数量 | 8 路模拟量输入 |
| 分辨率 | 16 位 |
| 支持信号 | 4~20mA 电流,0~10V /-10~+10V 电压信号 |
| 通道隔离 | 通道间隔离,抗共模干扰 |
| 采样周期 | 毫秒级高速采集 |
| 供电规格 | 24V DC |
| 总线接口 | S800 I/O 现场总线,连接 CI801 等通讯接口卡 |
| 工作温度 | -20℃ ~ +60℃ |
| 环境湿度 | 5~95% 无凝露 |
| 安装方式 | S800 I/O 单元机架插拔安装 |
| 诊断功能 | 断线检测、超量程、模块故障自诊断 |
| 合规标准 | IEC61131,电力石化行业认证 |

{“AIGC”:{“AIGC”:{“ContentProducer”:”001191440300MA5G49LC9K1TK01″,”ContentPropagator”:”001191440300MA5G49LC9K1TK01″,”Label”:”1″,”ProduceID”:”59kEU9UbHn5w9iFtnBm9eTTQDQr8SwJE”,”PropagateID”:”59kEU9UbHn5w9iFtnBm9eTTQDQr8SwJE”,”ReservedCode1″:{“SecurityData”:{“Type”:”TC260PG”,”Version”:1,”Bindings”:[{“Type”:”Hash”,”AlgID”:”2.16.840.1.101.3.4.2.1″,”Value”:null}],”PubSd”:[{“Type”:”DS”,”AlgID”:”1.2.840.113549.1.1.11″,”TBSData”:{“Type”:”Content”},”Signature”:”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″},{“Type”:”PubKey”,”AlgID”:”1.2.840.113549.1.1.11″,”KeyValue”:”MIIBIjANBgkqhkiG9w0BAQEFAAOCAQ8AMIIBCgKCAQEArAVi2zWWdM08/8wKe9jRsx2ZxA7LuTHZ0SRbgom7a8E/+Ourpf4nzrwt+Mhk+MNxy4mqCRaZQXMD/FsREyftmeaoSaPPLxtVdOKk5eqDli0YE/kZ+sdgygm2Neh9bowfFZgRARrBCLxR3WiM/BuOBnU1rIUVZI/KOA2+r2aba2bV5o8Rq9H4sI0YauBKcIVm0WULmPf+lnSlln5Hysf8xwOXgD9NImqOXhWIvdfbOiTw1z5CEeNeHrBqWek9lbSAEIPrm/85DmWKoNL0l8MnFOzvRxlhIVbGBGqB1X9Oh1+vlA0gkQb6Ofb7AlalWdbKXTRe9fEpg0ZxQ3YSZMxt1wIDAQAB”}]}},”ReservedCode2″:{“SecurityData”:{“Type”:”TC260PG”,”Version”:1,”Bindings”:[{“Type”:”Hash”,”AlgID”:”2.16.840.1.101.3.4.2.1″,”Value”:null}],”PubSd”:[{“Type”:”DS”,”AlgID”:”1.2.840.113549.1.1.11″,”TBSData”:{“Type”:”Content”},”Signature”:”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″},{“Type”:”PubKey”,”AlgID”:”1.2.840.113549.1.1.11″,”KeyValue”:”MIIBIjANBgkqhkiG9w0BAQEFAAOCAQ8AMIIBCgKCAQEArAVi2zWWdM08/8wKe9jRsx2ZxA7LuTHZ0SRbgom7a8E/+Ourpf4nzrwt+Mhk+MNxy4mqCRaZQXMD/FsREyftmeaoSaPPLxtVdOKk5eqDli0YE/kZ+sdgygm2Neh9bowfFZgRARrBCLxR3WiM/BuOBnU1rIUVZI/KOA2+r2aba2bV5o8Rq9H4sI0YauBKcIVm0WULmPf+lnSlln5Hysf8xwOXgD9NImqOXhWIvdfbOiTw1z5CEeNeHrBqWek9lbSAEIPrm/85DmWKoNL0l8MnFOzvRxlhIVbGBGqB1X9Oh1+vlA0gkQb6Ofb7AlalWdbKXTRe9fEpg0ZxQ3YSZMxt1wIDAQAB”}]}}}}}
产品深度介绍
ABB AI610(3BHT300000R1)是 S800 I/O 系列模拟量输入模块,为 ABB 800M DCS 系统配套,用于现场温度、压力、液位、流量变送器信号采集。模块具备 16 位高精度模数转换,支持电流、电压两种模拟信号,自带断线检测,变送器线路断开时 DCS 可直接触发报警。
单通道电气隔离,能够削弱工业现场电机、变频器带来的共模干扰。模块安装在 S800 I/O 机架,通过 I/O 总线与控制器通讯。广泛用于电厂、化工老 800M DCS 系统大修、备件更换,保留原有端子底座和现场仪表线缆,直接替换卡件。
应用场景与行业案例
DCS AI 卡件更换 AI610,最容易踩信号量程配置和两线制变送器供电的坑。很多现场直接上机替换,未重新确认通道信号类型,4-20mA 通道配置成电压模式,测点无读数或数值溢出。
典型应用场景:
- 火力发电 – 锅炉系统测点采集 汽包液位、炉膛压力、给水流量、烟气温度变送器信号采集,锅炉 DCS 核心模拟测点。
- 石油化工 – 炼化装置过程监测 精馏塔液位、原料流量、反应釜温度采集,连续化工工艺监测。
- 煤化工项目 – 老 DCS 维保改造 原有 ABB 800M 系统备件更新,S800 远程 I/O 站卡件更换。
- 造纸制浆 – 纸机工艺监测 蒸煮罐液位、药液压力采集,配套 ABB DCS 系统。
案例:河北某热电厂锅炉车间抢修 去年 9 月,锅炉汽包液位测点 AI610 模块通道损坏,2 个液位测点失效,运行人员只能依靠就地仪表监护,存在锅炉满水 / 缺水安全风险。 原厂订货周期 11 周,不能长期无监控运行。 采购找到我们现货 AI610 备件,工程师提前备份通道组态、信号类型、量程上下限。卡件上机,配置导入,变送器信号正常读取,DCS 画面液位恢复实时显示。